The Dual Link module automatically regulates the pH (acid dose) and chlorine produced by the eXO® iQ, eXO® iQ LS and Hydroxinator® iQ electrolysers. For optimal water balance and disinfection.
With the POD Kit supplied, sensor installation is easier and measurements are more accurate.
For which swimming pool ?
Maximum volume of treated water: Depending on the model of the associated chlorinator
pH dosage: Acid
Description :
User interface: Device’s interface (4-line, backlit LCD screen)
Calibration: Semi-automatic at 2 points pH 4 and pH 7 & ORP 470 mV (buffer solutions included)
Setpoints: Adjustable - Factory setting: pH = 7.2 / ORP = 700 mV
Sensor position: Vertical, on the POD (provided)
Safety: Overdosing safety, low measures, unplugged sensor
Sensor type (pH & ORP) | Combined process sensor, double junction and double porous, glass body |
Reading scale | 0.0 -12.0 pH - ORP: 100 - 1000 mV |
Reading accuracy | 0.1 pH - ORP: 10 mV |
Sensor Tolerances | 0-60 °C, water speed ≤ 2 m/s |
Maximum counter pressure (injection point) | 1.5 bar |
Peristaltic pH pump flow | 1.2 L/h |
Cell size (l x w x h) | 30.5 x 18.1 x 11.5 cm |
Warranty: 2 years
Accessories included in the pack:
- ORP sensor
- pH sensor
- pH 4 and pH 7 buffer solutions and ORP 470 mV buffer solutions (3 of each)
- Hole saw
- POD Kit
- Plumbing kit
Optional accessories:
- Intake pipe
- pH 4 and pH 7 buffer solutions and ORP 470 mV buffer solutions (6 of each)
- Winterizing cap
- 3m BNC cable extension
- Earthing anode